Search Article 
 
Advanced search 
Official publication of the American Biodontics Society and the Center for Research and Education in Technology
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL RESEARCH
Year : 2020  |  Volume : 11  |  Issue : 2  |  Page : 33-39

A Comparative Evaluation of Four Different Techniques for Determining the Accuracy of Root Canal Working Length: An In Vitro Study


Department of Conservative Dentistry and Endodontics, King George’s Medical University, Lucknow, Uttar Pradesh, India

Correspondence Address:
MDS, Professor (Junior Grade) Rakesh Kumar Yadav
Department of Conservative Dentistry and Endodontics, King George’s Medical University, Lucknow, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/denthyp.denthyp_37_19

Rights and Permissions

Introduction: Complete disinfection of root canal is one of the main objectives of root canal treatment. However, complete disinfection is only possible after correct determination of root canal working length. Thus, determining a correct working length is essential for endodontic success. Thus, the present study was conducted with the aim to comparatively evaluate the accuracy of four different techniques in determining root canal working length. Material and Methods: 30 freshly extracted human single-rooted teeth were taken. After sectioning the teeth at the cemento-enamel junction, K-Flexofile with size 10 was used to check the patency of canal and major foramen. Each sample was then subjected to all the four techniques. The four techniques used were conventional radiography, radivisiography, electronic apex locator (raypex 6) and cone beam-computed tomography. After calculating each root canal length of samples, their actual length was measured by using K- Flexofile until its tip became visible through the major foramen. The file was taken out when a magnifying glass showed its tip at the coronal border of major foramen. The adjustment of rubber stop was done according to the occlusal reference, and then the distance between the stop to the file tip was measured. Finally a comparison was done for each sample between the root canal length recorded with the four techniques and the actual length. Results: Mean of absolute differences with respect to actual length was lowest in case of electronic apex locator whereas, it was highest in case of cone beam-computed tomography. Conventional radiography and Radiovisiography had negative mean difference values that showed overestimated canal length. A significant difference was observed between cone beam-computed tomography and the other three techniques respectively (P < 0.05). Conclusion: Raypex 6 apex locator was more accurate than the other three techniques in determining root canal working length.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1077    
    Printed54    
    Emailed0    
    PDF Downloaded135    
    Comments [Add]    

Recommend this journal