Dental Hypotheses

ORIGINAL RESEARCH
Year
: 2020  |  Volume : 11  |  Issue : 4  |  Page : 112--120

Effects of New Modification in the Design of the Attachments Retaining Distal Extension Partial Denture on Stress Distribution Around the Abutments And Residual Ridges: An In Vitro Study


Mahabad Mahmud Saleh1, Dhia Aldori2 
1 Department of Prosthodontics, College of Dentistry, Hawler Medical University, Erbil, Iraq
2 Department of Prosthodontics, College of Dentistry, Al Kitab University, Altun Kupri, Kirkuk, Iraq

Correspondence Address:
Mahabad Mahmud Saleh
Department of Prosthodontics, College of Dentistry, Hawler Medical University, Erbil,
Iraq

Introduction: The aim of this in vitro study was to evaluate the effect of modification of the attachment on stress transmitted to the abutment tooth and residual ridges in lower unilateral distal extension partial dentures. Materials and Methods: An acrylic lower unilateral distal extension cast with the first premolar as the main abutment was constructed. Three types of commonly used extracoronal castable attachments were selected, namely: (1) Preci-vertix standard, CEKA attachment, (2) Preci-sagix mini size, CEKA attachment, (3) OT–cap normal, Rhein 83. They underwent a simple new modification and their effect on stress distribution was studied. Six attachment retained removable partial dentures were constructed: among them, three with nonmodified attachments, and three with modified attachments. Four strain gauges were installed on the acrylic cast to measure the microstrain induced around the abutment tooth and residual ridges. A unilateral static vertical load of 300 Newton was applied on the first premolar and the first molar at a crosshead speed of 2 mm/min and microstrain was recorded using specific miniature Universal Testing Machine. Data were collected and analyzed using the Wilcoxon test for comparison between attachments before and after modification. Results: The highest microstrain was recorded for modified OT cap and modified Preci-sagix attachment around the abutment tooth and residual ridges respectively. While modified PV attachment showed the lowest microstrain around abutment and residual ridges. Conclusion: Maximum strain induced around the tooth and residual ridges in cases of OT cap and Preci-sagix attachments. Among all attachments, the use of Preci-vertix showed better stress distribution around both abutment and residual ridges.


How to cite this article:
Saleh MM, Aldori D. Effects of New Modification in the Design of the Attachments Retaining Distal Extension Partial Denture on Stress Distribution Around the Abutments And Residual Ridges: An In Vitro Study.Dent Hypotheses 2020;11:112-120


How to cite this URL:
Saleh MM, Aldori D. Effects of New Modification in the Design of the Attachments Retaining Distal Extension Partial Denture on Stress Distribution Around the Abutments And Residual Ridges: An In Vitro Study. Dent Hypotheses [serial online] 2020 [cited 2020 Nov 30 ];11:112-120
Available from: http://www.dentalhypotheses.com/article.asp?issn=2155-8213;year=2020;volume=11;issue=4;spage=112;epage=120;aulast=Saleh;type=0