Dental Hypotheses

ORIGINAL RESEARCH
Year
: 2021  |  Volume : 12  |  Issue : 3  |  Page : 132--138

Diagnostic Accuracy of Cone-Beam Computed Tomography at Different Tube Voltages for Vertical Root Fractures in Endodontically Treated Teeth with Metallic Posts


Hoorieh BashizadehFakhar1, Behnam Bolhari2, Ahmad Reza Shamshiri3, Shirin Amini4, Paniz Ranji1 
1 Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
2 Department of Endodontics, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
3 Research Center for Caries Prevention, Dentistry Research Institute, Department of Community Oral Health, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
4 Private Dentist, Tehran, Iran

Correspondence Address:
Paniz Ranji
Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Tehran University of Medical Sciences, North Kargar Street, Tehran, Postal Code: 14399-55991
Iran

Introduction: The study evaluated the effectiveness of different tube voltages of the cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures in teeth with single root canals and posts. Materials and methods: Sixty single-canal and single-rooted extracted human mandibular premolars were selected, all of which were intact and contained no fractures. After disinfection, teeth crowns were sectioned and teeth canals were prepped and obturated by a method similar to the rotary technique. Root fractures were created in half of the teeth by applying controlled buccolingual force. Prefabricated metal posts were subsequently placed in all teeth using AH26 sealer. All teeth, both intact and fractured, were mounted in bovine ribs and X-rayed randomly using a CBCT device (Planmeca Romexis, Helsinki, Finland) with three tube voltages (min = 66 kVp, mid = 80 kVp, and max = 92 kVp). Three experienced maxillofacial radiologists observed and commented on the images. Research data were analyzed using SPSS-25 software. Results: Images taken by kVp min were removed from further statistical analysis due to a lack of diagnostic information. For mid (80) and max kVp (92), the sensitivity values were 86.6% and 60 % (P = 0.04), and the specificity values were 33.3% and 30%, respectively (P = 0.45). Overall, observers’ opinions were more alike concerning images taken with kVp mid than kVp max. Conclusion: Apparently, images taken by a tube voltage of 80 kVp are more efficient in the diagnosis of root fractures.


How to cite this article:
BashizadehFakhar H, Bolhari B, Shamshiri AR, Amini S, Ranji P. Diagnostic Accuracy of Cone-Beam Computed Tomography at Different Tube Voltages for Vertical Root Fractures in Endodontically Treated Teeth with Metallic Posts.Dent Hypotheses 2021;12:132-138


How to cite this URL:
BashizadehFakhar H, Bolhari B, Shamshiri AR, Amini S, Ranji P. Diagnostic Accuracy of Cone-Beam Computed Tomography at Different Tube Voltages for Vertical Root Fractures in Endodontically Treated Teeth with Metallic Posts. Dent Hypotheses [serial online] 2021 [cited 2022 Jan 27 ];12:132-138
Available from: http://www.dentalhypotheses.com/article.asp?issn=2155-8213;year=2021;volume=12;issue=3;spage=132;epage=138;aulast=BashizadehFakhar;type=0